s
ARX SERIES Petrol Engine Generators
SQ SERIES Diesel Engine Generators
KJ SERIES Diesel Engine Generators


ARX SERIES

PETROL ENGINE GENERATORS

Kubota's ARX series clean emission generators are built to last in an ISO 9002 certified production plant. This compact and lightweight series, powered by Kubota's highly durable OHV engines, is rugged enough for heavy duty works at construction sites yet portable enough for recreational use or as an emergency household power source. Noise levels are kept to a minimum with Kubota's superb combustion chamber, original sound reduction design and parts. So, if you are looking for a more reliable and quiet way to generate power, the ARX series is for you.

Reliable Start Ups
· Engines used to power the ARX series are equipped with an automatic decompression system and a maintenance free electronic ignition device to provide easy starting in any type of weather. The automatic decompression system, which has significantly reduced the recoil starter's pulling force, has now made it easy for almost anybody to start the engine. The easy 'One Push' electric start is a standard feature on ARX5500B and ARX6500B.

To the top...

Kubota's OHV
Kubota's own air-cooled, 4-cycle OHV engines achieve greater combustion efficiency by placing the valve over the cylinder. This way air and fuel are more completely mixed together to achieve greater thermal and fuel efficiency.

Economical and Safe Operation
Improved fuel economy and reduced oil consumption contribute to economical operation. Kubota's OHV engines consume 25% less fuel and 50% less oil than comparable side valve engines. As a safety measure, the Oil Watch system automatically stops the engine operation before the oil reaches an unsafe level.

Lower Noise Level
Kubota's original sound reduction design focuses on air intake, combustion and exhaust systems. Larger air cleaners, Kubota's hight efficient combustion chambers, oversized mufflers help reduce noise levels.

Comparison of Noise Levels

Model 50Hz 60Hz
ARX2500
70 73
ARX4000 71 73
ARX5500 74
ARX6500 74
ARX5500B 74 76
ARX6500B 74 77

(1) The sound levels are expected values. The measurements were made in Db(A) by applying the mean figure of the sounds measured at 4 points from a distance of 7m.
(2) Testing method was done according to Jem 1420 standard.

To the top...

Stable Power Supply
Either the brushless Condenser Load Compensation (CLC) system or the brush type automatic Voltage Regulator (AVR) system is used for the generator unit. Both systems ensure consistent output with very little voltage fluctuation.

Convenient Operation
All connectors, indicators and controls are grouped together for convenient operation. Solve the problem of accidental cord unplugging. Built-in circuit breakers/protectors provide additional safety for AC and DC circuits.


SPECIFICATIONS

Model ARX2500 ARX4000 ARX5500B ARX6500B
Generator
Frequency
HZ 50
Max Output kVA 2.1 3.5 4.8 5.4
Rated Output V 1.8 3.0 4.0 4.5
Voltage V 240 240 240 240
Current A 7.5 12.5 16.7 18.8
To the top...
Power factor %
100
Design
Single phase-Revolving -field type
Excitation
Single phase Self-excited type
Voltage Compensation CLC
AVR
Insulation
Class B
Over Current Protection
AC-Circuit Breaker
Engine
Type
Air-cooled 4 cycle OHV Petrol Engine
Model GH170-1-DG GH280-DG GH400-DGS GH400-DGS
Displacement ml 169 274
389
Fuel Tank Capacity litre/Gal 14 (3.7) 17.8 (4.7)
20 (5.3)
Capacity in rated output (approx hours) 11.6 10.5 8.5 7.5
Fuel Unleaded Petrol
To the top...
Lubricating Oil API Type SE,SF or SG class engine oil 10W-30
Starting System Recoil Electric & Recoil
Total Dry Weight kg/lbs 45 (99) 63 (138.9) 98 (216) 102 (224.9)
Total dimensions (L x W x H) mm 540 x 440 x 500 605 x 455 x 565 700 x 505 x 605

*Battery is not included but a battery tray is.
Injury can occur: Do not connect generator to an electrical system unless an isolation switch has been installed.

Special Features

Models: ARX2500, ARX4000, ARX5500B, ARX6500B
Frequency (Hz) 50
Kubota 4-Stroke OHV Engine
Oil Watch
Electronic Ignition
Auto Idler
Electric Start
Battery Tray
Fuel Gauge
Voltmeter
Full Wrap Around Frame

To the top...

Contact BC Machinery for more information
Phone: (08) 89721988
Email: sales@bcmachinery.com.au


KUBOTA SQ SERIES
DIESEL ENGINE GENERATORS


Kubota introduces a new line of low noise heavy-duty 4 pole diesel generators, the SQ Series. Powered by Kubota's own cleaner emission and highly durable E-TVCS combustion system diesel engines, the SQ series ensure a much quieter, more efficient, and longer service life practically anywhere you go

Super Quiet Performance 61-64 dB(A)

  • Sound level has been lowered by the over-sized muffler
  • A special 2 stage muffler system is used in generators powered by V3300 to reduce noise even further
  • Noise within the generator unit has been lowered by improving the noise reduction enclosure and by adding a new noise absorbing duct with 3 air intake holes
  • Kubota not only reduced fan related noise with this larger-diameter, slower speed fan, but also able to maintain the same cooling effect as one running at normal speed
  • A longer air cleaner inlet hose is used to keep the low frequency noise down.

To the top...
Operator Friendly

  • The SQ series is equipped with large capacity bottom mounted fuel tanks to prevent fuel spills inside the enclosure.
  • The locking fuel cap is placed to avoid damage and simplify refueling.
  • The advanced design and superior engineering minimises both space and weight.
  • Transportability is improved with slots on each side of the machine for safe forklift truck transportation.
  • Four tie down points and sturdy lifting eyes further enhance hoisting and transportation.
  • Every time the engine key is turned ON, air is automatically purged from the fuel system.
  • Locking Control Panel Door shields instrument panel from the elements and permits observation of all key functions without opening the door.
  • Automatic start system for standby applications, wiring and space have been provided as standard equipment.

To the top...
Safety and Maintenance

  • The cables enter the load centre through a conduit entry placed on the bottom of the unit. Once the terminals are connected, the load centre can be locked to prevent inadvertent contacts.
  • In case of abnormal oil pressure/water temperature, or in case the fan belt breaks', the emergency stop system will automatically shut the unit down. Emergency requires immediate action. With the emergency stop button placed on the outside rather than on the inside, it's now possible to stop the unit in less time.
  • Large, removable doors feature heavy duty steel hinges and recessed locking door latches safeguard against unauthorised use, allow safe, unattended operation and easy maintenance.
  • Engine oil and coolant drain extensions are provided to ease regularly scheduled maintenance.Oil gauge, oil filter, oil replenishment port, fuel filter, water reserve tank, battery and air cleaner are located on one side for quicker inspection and maintenance.

Stable Load
Solid state voltage regulation maintains excellent stability during changing load conditions. Quick response automatically provides stable power to sensitive equipment.

SPECIFICATIONS

MODEL UNIT SQ-1120 SQ-1150 SQ-3140 SQ-3200 SQ-3300
GENERATOR
Design
Revolving field, self-excited brushless AC generator
Frequency Hz
50
Standby Output kVA (kW) 11.8 (11.8) 16.0 (16.0) 15.4 (12.3) 22.0 (17.6) 33.0 (26.4)
Prime Output kVA (kW) 11.2 (11.2) 15.0 (15.0) 14.0 (11.2) 20.0 (16.0) 30.0 (24.0)
To the top...
Voltage - 3 Phase
415
Voltage - Single Phase
240
240
Armature Connection
Series
Star with neutral
Phase & Wire
1-4
3-12
Power Factor
1.0
0.8
No. of Poles
4-pole
Insulation
Class H
Voltage Regulation %
±1.5 (No load to full load)
Type of Coupling
Direct Coupled
Diesel Engine
Model D1703-EBG V2203-EBG D1703-EBG V2203-EBG V3300-EBG
Design
Vertical, water-cooled, 4-cycle diesel engine
No. of Cylinders 3 4 3 4 4
To the top...
Bore x Stroke mm
87 x 92.4
98 x 110
Displacement L 1.647 2.197 2.197 1.647 3.318
Engine Speed rpm
1500
Continuous Rated Output kW 13.6 18.4 13.6 18.4 26.8
Lubricating Oil
API service class CD or higher
Oil Capacity L 5.6 7.6 5.6 7.6 13.2
Coolant Capacity L 5.5 6.3 5.5 6.3 8.2
Set
Fuel
Diesel fuel No. 2 (ASTM D975)
Fuel Consumption (at full load) L/h (GPH) 3.9 (1.1) 5.5 (1.5) 3.8 (1.0) 5.3 (1.4) 7.7 (2.0)
Fuel Tank Capacity L
62
68
Continuous Operating Hours (at ¾ load) hrs 20.7 15.1 21.4 15.5 11.5
Battery
80D26R (55Ah)
130E41R (92Ah)
Starting System
Electric
L X W x H mm
1675 x 780 x 970
1935x860x995
To the top...
Approx Net Wt kg 640 730 640 730 880
Sound Level (full load at 7m) dB (A) 61 63 61 63 64
Amps at Prime
Single Phase 240V A 46.7 62.5 12.5 18.1 27.1
Three Phase 415V A 19.5 27.8 41.7


Contact BC Machinery for more information
Phone: (08) 89721988
Email: sales@bcmachinery.com.au

To the top...


KUBOTA KJ SERIES
DIESEL ENGINE GENERATORS


Kubota's untiring quest for quality led to the development of a new line of heavy-duty 4-pole generators, the KJ Series. The power source is Kubota's own Super 03 Series diesel engines with emission levels far below the set standard according to more efficient, and much longer service life anywhere you need fast, safe and economical electrical power. Every generator in this series is designed, assembled, and tested to guarantee maximum performance and compatibility. KJ Series' alternator and the engine production plants have been approved and awarded ISO 9002 certification by Lloyd's Register Quality Assurance (LRQA). When the label reads Kubota, quality is assured.
To the top...

Dependable Power

  • Brushless Alternator - This brushless, self-excitation type alternator is designed to be used in a wide variety of difficult starting conditions. Its Load Acceptance Module (LAM), enables the engine to accept larger load impacts and to regain its rated speed more quickly. Its convertible (50 Hz) electronic regulator is powered independently from the voltage detection circuit, therefore regulation is not affected by distortions generated by the load.
  • Transistor Automatic Voltage Regulator (AVR) - All KJ Series generators are equipped with a transistor AVR to regulate a stable flow of current. In addition, any local condition can be matched by using the voltage adjustment.
  • Reduced Sound and Vibration - Kubota's low noise design features quieter engines with the TVCS combustion system, as well as sound attenuated enclosures which effectively reduce all sound levels. Integral vibrations has also been reduced by adding rubber isolating pads in critical areas.

Increased Safety

  • Automatic Shutdown Mechanism - Should any abnormality occur in oil pressure or water temperature, this mechanism automatically stops the engine before it can be damaged.
  • Emergency Unit - Kubota gathered the emergency relay, timer relay, and safety relay into one unit to save space, simplify the wiring scheme, and to improve protection against water, dust, and vibration. An external key switch is part of the standard control system for KJ generators. In addition, a manual engine shutdown lever is available as an emergency backup.
  • Protective Design - All rotating parts of the generator have been enclosed in a sturdy cabinet for maximum operator safety.

To the top...
Ease of Operation and Portability

  • Convenient Front Panel Control - All switches and lamps are conveniently located in the centre of the front panel for maximum accessibility.
  • Transportability Enhanced by Twin Point Lifting Eye - Twin point lifting eye makes it easy to transport all KJ Series generators.

Simple Maintenance

  • Ease of Access - Oil, fuel, water, and filters are all located on one side for easy maintenance.
  • Automatic Air Bleeding - Air bubbles which can rob the engine of its power are automatically removed from the fuel line.
  • Easy-to-Mount and Remove Battery Pack - The battery pack, located in the rear of the generator, can be easily removed through the back panel.

Cleaner, Quieter, and More Reliable Super 03 Series Diesel Engines

  • Kubota's original TVCS combustion system improved air/fuel mixture, resulting in cleaner engine emissions which comply with US CARB ULGE regulations.
  • Sound levels during load and no-load operations are kept to a minimum with Kubota's world renown diesel engine development technology and the superb TVCS combustion system.
  • Super glow system comes as standard equipment to shorten preheating time and quicken engine start ups in cold temperature.
  • Sturdy built Super 03 Series engines promise great reliability and long service life with advantages to meet most any application.
  • In addition, the Super 03 Series is also designed against asbestos pollution.

To the top...

SPECIFICATIONS

Generator Model KJ-S130VX KJ-S170FX KF-T130DX KJ-T180VX KJ-T230FX
Type Revolving field, self-generating brushless AC generator Revolving field, self-generating brushless AC generator
Frequency Hz
50
50
Rated Output kVA 12.5 17.0 12.5 18.0 23.0
Rated Output kW 12.5 17.0 10.0 14.4 18.4
No. of Phases
1
3
Voltage (AC) V 240 240 240/415 240/415 240/415
To the top...
Current A 52.1 70.8 17.4 25.0 32.0
Power Factor %
100
80
No. of Poles
4
4
Rating
Continuous
Continuous
Insulation Class
H
H
Drive
Direct Drive
Direct Drive
Engine Type Vertical, water-cooled, 4-cycle diesel engine Vertical, water-cooled, 4-cycle diesel engine
Model V2203 f2803 D1703 V2203 F2803
No of Cylinders
4
5
3
4
5
Bore x Stroke mm
87 x 92.4
87 x 92.4
Total Displacement mm 2197 2746 1647 2197 2746
To the top...
Revolutions per minute 1500 1500 1500 1500 1500
Continuous rated output kW(PS) 23.0(16.9) 28.7 (21.1) 17.2(12.6) 23.0(16.9) 28.7(21.1)
Lubricating Oil API service class CC or CD 10W30 API service class CC or CD 10W30
Oil Capacity Litre 8.7 10.5 6.3 8.7 10.5
Coolant Capacity Litre 7.9 9.4 6.9 7.9 9.4
Fuel Set Diesel No 2. (ASTM D975) Diesel No 2. (ASTM D975)
Fuel Tank Capacity Litre 37 60 37 37 60
Fuel Consumption (at rated output) 5.2 l/h 6.5 l/h 3.9 l/h 5.2 l/h 6.5 l/h
Starting Method Electric Electric
To the top...
Battery Capacity Ah
70
70
80

Dimension
Length mm
Width mm
Height mm


1518
650

971

1643
740

996

1423
650
971

1518
650
971

1643
740
996
Total Dry Weight kg 505 630 470 505 600
Sound level during Rated output at 7 meters dB(A) 75 76 73 75 76
Emergency Stop Mechanism In case of abnormal oil pressure or water temperature
Security measures Door, fuel cap, control protection panel and radiator cap are lockable Door, fuel cap, control protection panel and radiator cap are lockable
To the top...
Control Panel

1) AC Voltmeter
2) Frequency meter

3) AC Ammeter
4) No Fuse Breaker
5) Pilot Lamp
6) Warning Lamp
7) Main Switch
8) AC Voltmeter Phase Selector Switch

9) Voltmeter Adjuster
10) AC Ammeter Phase Selector Switch
11) Hour Meter
12) IP56 Socket Outlets

a) 500V 3-phase (32Amp) 5 pin Clipsal Cat No: 56s0532-RO
b) 250V Single Phase (15Amp) 3 pin Flat Clipsal Cat No: 56s0315-RO

Injury can occur: Do not connect generator to an electrical system unless an isolation switch has been installed.

Contact BC Machinery for more information
Phone: (08) 89721988
Email: sales@bcmachinery.com.au


Home | Product Information | Kubota Engine and Generators
CONTENT DISCLAIMER
The information contained within BC Machinery on line has been derived from various competent sources and has been checked and authorised by Baynes Pty Ltd T/A BC Machinery prior to publication. Whilst every care has been taken in the preparation of the site content, Baynes Pty Ltd T/A BC Machinery shall not be liable, either directly or in any consequential way, for acts or omissions by any party in the direct or indirect use of the information described herein.
Due to ongoing product development, Baynes Pty Ltd T/A BC Machinery reserves the right to change without notice, any product details including specifications, appearance and performance.
Website last updated 24th May 2006